Model 500 Packing Glands

Model 500 Packing Gland

Body A B C CAP D E F
b15 M20 x 1.5
O-Ring Seal
.50 3.31 c12 3/4 NPT .62 1.25
b16 M25 x 1.5
O-Ring Seal
.69 3.31 c13 1 NPT .75 1.39
b17 M32 x 1.5
O-Ring Seal
.75 3.31 c14*   .75 .36
b18 3/4 NPT .62 3.51        
b19 1 NPT .75 3.64        
b20 1-1/4 NPT .75 3.67        

* If conduit connection not required add "H" prefix to assembly number

Materials:

Body, Cap, Jam Nut 303 Stainless Steel
Insert, Follower 6061-T6 Anodized Aluminum
Grommet 57 Durometer Flurocarbon
Illustration of Two-piece Follower Construction
Illustration of Two-piece Follower Construction

The Model 500 was designed to allow up to 8 vibration sensor leads to be brought through a single port. The Model 500 uses a split grommet along with inserts and followers of two-piece construction. Two-piece construction eliminates the need for oversize follower holes, thus providing more support for the grommet at the wire hole while allowing for more wires in a given diameter.

 

Assembly Numbers 8 Wires:

Body Cap .156 Grommet Wire Hole Dia.
b15 c12 See Note 2
b16 c12
c13
508
508E
b17 c12
c13
508A
508F
b18 c12
c13
508B
508G
b19 c12
c13
508C
508H
b20 c12
c13
508D
508I

Note 1: Any Model 300 cartridge assembly can be used in any Model 500 body with a c12 cap by the addition of an adapter sleeve (Part No. 500-10).
Note 2: The through hole of the b15 body is too small for use with eight leads. Consult with factory for application restraints.